Hot Water Pump Circulating Pump For Hot Water?

Circulating pump for hot water? - hot water pump

It was a circulation pump installed in my house, take hot water for ever, to reach other parts of the house. The past year and I have the same situation. I remember that the plumber said that I disconnect the pump when it gets too hot. Will it work? If not, I get another?

3 comments:

dunroami... said...

Things that may be several:
1) In the single-phase motors, there is a capacitor (a cylindrical piece of the engine mounted on the outside), sending the engine on the right track.
2) The pump can "gum", ie not turning up when the device is switched
3) Maybe not the fuel pump

4) is not working properly with an air that needs to be cleaned installed.

Unscrewed in the first two cases, the central cap in the middle of the plate, and so (access to the top of the tree does not get wet, there is) a seal and turn the tree in the right direction with a screwdriver into the slot in the shaft . He turns the engine now? If so back after a short time. Start on your own? If yes, stickers. If cost to replace a capacitor on.
If all tests are on the power with a voltmeter to the debt.
Pump should operate for many years before replacing.
If not properly installed, the engine should not move vertically upwards and this is not self-cleaning in This position. The motor must be horizontal.

I hope this helps (as they say :-)

dunroami... said...

Things that may be several:
1) In the single-phase motors, there is a capacitor (a cylindrical piece of the engine mounted on the outside), sending the engine on the right track.
2) The pump can "gum", ie not turning up when the device is switched
3) Maybe not the fuel pump

4) is not working properly with an air that needs to be cleaned installed.

Unscrewed in the first two cases, the central cap in the middle of the plate, and so (access to the top of the tree does not get wet, there is) a seal and turn the tree in the right direction with a screwdriver into the slot in the shaft . He turns the engine now? If so back after a short time. Start on your own? If yes, stickers. If cost to replace a capacitor on.
If all tests are on the power with a voltmeter to the debt.
Pump should operate for many years before replacing.
If not properly installed, the engine should not move vertically upwards and this is not self-cleaning in This position. The motor must be horizontal.

I hope this helps (as they say :-)

Robert L said...

If the pump does not work, then check to ensure the power that remains. If so, then you probably need a new one. This time, with a thermal protection occurs, you will look long to see if it gets hot. Automatically stops and starts with the temperature.